CEL-200 SERIES DIGITAL SOUND
LEVEL METERS
Go to
Preface
HB3348-01
OPERATOR’S MANUAL
CASELLA CEL
CASELLA CHINA(中国)
CASELLA
USA
CASELLA
ESPANA
S.A.
Regent House
17
Old
Nashua
Ro ad,
地址
北京东城区东方广场W1911
Polígono
Európolis
Wolsley Road
#
15,
Am h er st
Calle
C,
4B
Kempston
NH
03031
邮编: 100738
28230
Las
Rozas
-
Madrid
Bedford
USA
电话: 0086 10 85183141
Spain
MK42
7JY,
U. K.
Toll
Fr ee:
+1
(800)
366
2966
传真: 0086 10 85183143
Phone:
+
34
91
640
75
19
Phone:
+44
(0)
1234
844
100
电子邮件:
info@casellameasurement.cn
网址: www.casellachina.cn
Fax:
+
34
91
636
01
96
Fax:
+44
(0)
1234
841
490
Fax:
+1
(603)
672
8053
E-mail:
E-mail:
info@casellaUSA.com
E-mail:
info@casellameasurement.com
online@
casella- es. com
Web :
www.casella-es.com
Web :
www.casellameasurement.com
Web :
www.casella
USA.com
Vue de la page 0
1 2 3 4 5 6 ... 20 21

Résumé du contenu

Page 1 - LEVEL METERS

CEL-200 SERIES DIGITAL SOUND LEVEL METERS Go to Preface HB3348-01 OPERATOR’S MANUAL CASELLA CEL CASELLA CHINA(中国) CASELL

Page 2 - PREFACE

4. Press Right key (B) to make changes to each setting as described below in sections A - G. Figure 7 Instrument Settings 5. Current settings wi

Page 3 - 1. MANUAL CONVENTIONS

C. MEASUREMENT RANGE (30 – 100dB or 60 – 130dB) Care should be taken to select the correct measurement range depending on the noise clim ate being m

Page 4

Figure 8 Logging Interval Screen – CEL-246 only Back to Index 12

Page 5 - 6. USB PC Output. 7

7. CONFIGURATION MENU The Configuration Menu (Refer to Figure 9) is used to make changes to the Display Contrast, Calibration Level and the Signal

Page 6 - 3. PREPARATION FOR USE

8. MEMORY AND TIME/DATE SETTINGS (CEL-242/246) This screen only appears when the instrument is switched on and only on CEL-242 or CEL-246 models. F

Page 7 - 4. GENERAL OPERATION

9. MEMORY DELETION SCREEN (CEL-242/246) This screen is accessed from the Time and Date screen described above. Initially press the Right key (B) if

Page 8 - 5. CALIBRATION

10. SET TIME AND DATE SCREEN CEL-242/246 This screen is accessed from the Time and Date screen described above. When this screen is accessed (Refer

Page 9 - 6. INSTRUMENT SETTINGS

12. EQUIPMENT SPECIFICATION SPECIFICATION CHARACTERISTICSSTANDARDS IEC 61672-1 2002-5 (Electro-Acoustics – Sound Level Meters) Gro up ‘X’ instrument

Page 10

Battery Life Typically 35 hours. Power Consumption ~65mA. ELECTROMAGNETIC COM PATIBILITY Instrumentation is designed and tested to comply with the fo

Page 11

13. SERVICE AND WARRANTY The manufacturer undertakes to rectify any defect in the instrument directly attributable to faulty design or assembly and

Page 12 - Back to

PREFACE Back to Cover1. MANUAL CONVENTIONS This section of the manual details the priority of Warnings, Cautions and Notes that may apply throughout

Page 13 - 7. CONFIGURATION MENU

14. ENVIRONMENTAL CONSIDERATIONS WEEE DIRECTIVE The WEEE directive aims to raise the level of recycling of electrical and electronic equipment (EEE

Page 14

15. DECLARATION OF CONFORMITY Back to Index END 21

Page 15

1. MANUAL CONVENTIONS PRIORITY ONE PERSONAL SAFETY. When a WARNING is included in the text, the WARNING will always precede the text it applies t

Page 16 - 11. SWITCH OFF

2. INTRODUCTION CEL-240, 242, 244 and CEL-246 Congratulations on your purchase of a CEL-200 Series Digital Sound Level Meter, subsequently referre

Page 17 - 12. EQUIPMENT SPECIFICATION

Figure 1 CEL-200 Series Digital Sound Level Meter 1. Microphone. 2. Power ON / OFF key. 3. Display. 4. Left Key. 5. Right Key. 6. USB PC

Page 18

3. PREPARATION FOR USE PROCEDURE (Refer to Figure 2) 1. Open the Battery Cover. 2. Check the battery compartment is clean and dry. 3. Fit three

Page 19 - 13. SERVICE AND WARRANTY

4. GENERAL OPERATION 1. Press and release the Power ON/OFF key to switch ON. During the software initiation the screen will display the firmware v

Page 20

4. A Bargraph (Refer to Figure 4 [A]) or Time History (Refer to Figure 4 [B]) will be displayed. Refer to INSTRUMENT SETTINGS to change the Time an

Page 21

Figure 5 Calibration Mode Screen 5. Press left key (A) to perform a calibration, or press the right key (B) to Exit. When calibration is complete,